CIRS 062MQA超声波测试模体描述

The design intent of  062MQA is to provide a tool that can be used for both electron density calibration and image quality assessment of Cone Beam CT systems integrated in radiation therapy devices. The electron calibration function of the phantom enhances the outcome of the adaptive radiation therapy while the image quality features address the fine balance between optimizing image quality while minimizing radiation dose. 

The 062MQA CBCT Electron Density & Image Quality Phantom consists of several sections: a 100mm thick body slab, a 100 mm thick CBCT Image Quality phantom, a 50mm thick Electron Density Phantom, and a Bolus consisting of a 37.5mm thick uniform slab, a 12.5mm thick uniform slab and a 50mm thick uniform slab.

The 100 mm thick body section has a ce待删除信息al hole that receives the CBCT Image Quality Phantom. Each Bolus slab is drilled to accommodate an ion chamber insert and allow for ion chamber measurements regardless of the position of the Image Quality Insert. The thicknesses of the sections were selected to allow for positioning of any of the layers containing the Image Quality features in the ce待删除信息al axis of the beam. Also sections of different thickness decrease the increment with which the electron density section can be offset from the ce待删除信息al axis. 

The phantom support along with laser alignment marks allow for easy and quick positioning of the phantom on the accelerator couch. The phantom is placed on the support rails with the help of machined grooves.  Buffer plates are provided to decrease the artifacts from the support device and to allow the user to access the handles on the support plates. The leveling of the support and implicitly the phantom is done by adjusting leveling feet.

 

美国CIRS 062MQA特点: 深圳市展业达鸿科技有限公司

  • Perform all CT Image QA tests for AAPM TG Report #1

  • Use ionization chambers for dose measurements

  • Perform dose measurements using Ion chamber 

  • Calibrate Electron Density in multi-slice CT and Cone Beam CT

  • Perform ce待删除信息al axis and off-set measurements 
  • Position simulated tissue materials in CT & CBCT energy range at 17 different locations

  • Optimized for volumetric imaging

  • Quick positioning and customized loading configurations www.thingstest.com 

The One Tool Solution for Electron Density Calibration & Image Quality Assessment 

CBCT Image Quality Phantom

The Phantom is comprised of four layers: spatial resolution, CT number linearity/slice thickness, low co待删除信息ast and uniformity. The positioning of the different layers of the CBCT Image Quality phantom at the ce待删除信息al axis can be done with the phantom in the 100mm body section or with the phantom placed directly on the support device. com 

Spatial Resolution Layer Tel:0755-22934009      

The Spatial Resolution Layer is designed to evaluate the spatial resolution of IGRT systems. Line pair patterns from 1 lp/cm to 16 lp/cm are embedded in the background. In order to minimize artifacts, each line pair pattern is made from a material with 350HU greater than the background attenuation. The line pair patterns are 3D patterns 12mm in height along the longitudinal axis of the CBCT Image Quality Phantom. The spatial resolution targets are arranged in a circular pattern.

062QA_CTSlice_PHO.JPG

CT Number Linearity and Slice Thickness Layer The CT number Linearity and Slice Thickness Layer is designed to determine Co待删除信息ast-to-noise Ratio, Hounsfield number accuracy and Slice Thickness Sensitivity. Six rods made of Air, Low Density Polyethylene (LDPE), Polystyrene, Acrylic, Delrin and Teflon are used to measure the CnR and Hounsfield number Accuracy. Three angled air channels arranged in an equilateral triangle can be used to assess Slice thickness sensitivity. Tel:86-755-22934005

  062QA_LowCo待删除信息ast_PHO.jpgLow Co待删除信息ast Layer

The Low Co待删除信息ast Layer is intended to assess the system's ability to detect small differences in co待删除信息ast. It contains three sets of low co待删除信息ast rods with linear attenuation differences of 0.5%, 1% and 2% relative to the background material. The diameters of the low co待删除信息ast rods were chose to provide a 0.5 ratio between two adjacent rods by cross section and volume. Additional features are designed to evaluate the magnification on the orthogonal axes of the transversal image and as input for calculation of the Point Spread Function and subsequent calculation of Modulation Transfer Function. Tel:86-755-22934005

062QA_Uni_PHO.JPGUniformity Layer

The Uniformity Layer is designed to measure the system’s ability to produce uniform images across the field of view of an object with highly homogeneous physical properties in all directions. 


 

Electron Density Phantom

The Phantom consists of nested disks made from Plastic Water®. The nested disks allow simulation of both head and abdomen phantom configurations. Eight different tissue equivalent inserts can be positioned at 17 different locations within the scan field. The geometry of the phantom also enables the user to take measurement offset from the ce待删除信息al axis.

  Tel:0755-22934009      

NOTE: This product or an optional accessory of this product requires a CIRS dosimetry c待删除信息ity code before an order can be placed. Please refer to the Dosimetry C待删除信息ity Codes document to identify the CIRS code for the probe you intend to use with this product.

 